MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
You will find suitable crimp housings in product group F1444.
You will find suitable power supply cables (export) in product group G2351.
You will find suitable power supply cables in product groups G2313, G2315 and G2319.
You will find suitable connectors here.
Features
• Open frame • Contact pin for nylon-crimp terminals • Universal input • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: short circuit/over load/over voltage • Built-in remote On/Off control • Peak load capability
Technical Specifications
Input Voltage:
90...264V AC (47...63Hz)
127...370V DC
Input Inrush Current, Max.:
35A
Leakage Current, Max.:
1mA
Output Voltage Adjustment:
±10%
Over Load Protection:
122...160%
Withstand Voltage
I/P-O/P:
3000V AC
I/P-FG:
1500V AC
O/P-FG:
500V AC
Operating Temperature:
-20...+70°C
Weight:
240g
I/P = Input, O/P = Output, FG = Frame Ground
Part Nr.
UA
IA
PA
DUA
URN
h
[V]
[A]
[W]
[%]
[mVp-p]
[%]
LPS-50-3.3
3,3
0...10
33
3
50
75
LPS-50-5
5
0...10
50
3
50
81
LPS-50-12
12
0...4,2
50,4
2
80
82
LPS-50-15
15
0...3,4
51
2
80
84
LPS-50-24
24
0...2,1
50,4
1
80
85
LPS-50-48
48
0...1,1
52,8
1
100
86
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency
Note
These power supplies are considered as a component that has to be installed in a final equipment.