MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Enclosed type for PCB mounting • Universal input • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: short circuit and over load • Low no load power consumption
Technical Specifications
Input Voltage:
85...265V AC
Input Inrush Current, Max.:
3mA/100V DC
Leakage Current, Max.
(VDS 700V/TA 25°):
100µA
No Load Power Consumption, Max.:
<150mW
Over Load Protection:
>105%
Input Side:
Internal Fuse
Output Side:
Thermal Cut-off At 140°C
Withstand Voltage I/P-O/P:
4000V AC
Insulation Class:
B
Operating Temperature:
-20...+70°C
I/P = Input, O/P = Output
Part Nr.
UA
IA
PA
DUA
URN
h
[V]
[mA]
[W]
[%]
[% of UA]
[%]
HS40003.3
3,3
900
3
±1
1,2
³65
HS40005
5
600
3
±1
1,2
³70
HS40009
9
330
3
±1
0,55
³70
HS40012
12
250
3
±1
0,25
³70
HS40015
15
200
3
±1
0,13
³70
HS40018
18
167
3
±1
0,11
³70
HS40024
24
125
3
±1
0,1
³70
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency