MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
You will find suitable power supply cables in product groups G2121, G2123 and G2128.
You will find suitable power supply cables (export) in product group G2351.
You will find installation material in product group L9985.
You will find suitable filters in product group D3213. You will find suitable connectors here.
Features
• Enclosed case (U-bracket) • Universal input • Built-in active PFC function • DC OK active signal and redundant function • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: over load, over voltage and over temperature • EMC standards: EN 55032 Class B, EN 55014 • Safety standards: UL 62368-1, EN 62368-1, EN 60335-1 (Except for 55V) • 3 years manufacturer warranty
Technical Specifications
Input Voltage:
90...264V AC (47...63Hz)
127...370V DC
Input Inrush Current, Max.:
80A
Leakage Current, Max.:
0,75mA
Over Load Protection:
110...140%
Withstand Voltage
I/P-O/P:
3750V AC
I/P-FG:
2000V AC
O/P-FG:
1250V AC
Operating Temperature:
-30...+70°C
Weight:
468g
I/P = Input, O/P = Output, FG = Frame Ground
Part Nr.
UA
IA
PA
Uadj
DUA
URN
h
[V]
[A]
[W]
[V]
[%]
[mVp-p]
[%]
UHP-200R-3.3
3,3
40
132
3,2...3,5
2
150
89
UHP-200R-4.2
4,2
40
168
3,6...4,4
2
150
90
UHP-200R-5
5
40
200
4,5...5,5
2
200
91
UHP-200R-12
12
16,7
200,4
11,4...12,6
1
240
93
UHP-200R-15
15
13,4
201
14,3...15,8
1
240
94
UHP-200R-24
24
8,4
201,6
22,8...25,2
1
240
94
UHP-200R-36
36
5,6
201,6
34,2...37,8
1
240
94
UHP-200R-48
48
4,2
201,6
45,6...50,4
1
300
94
UHP-200R-55
55
3,6
201,6
45...58
1
360
94
UA = Output Voltage, IA = Output Current, PA = Output Power, Uadj = Output Voltage Adjustment, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Typ. Efficiency
Note
These power supplies are considered as a component that has to be installed in a final equipment.