MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Single phase PCB-mounting filters, Aluminium case • Low profile • FN406B-_: Suitable for medical applications, without Y2-capacitor
Technical Specifications
Continuous Operating Voltage, Max.:
250V AC, 50/60Hz
Dielectric Strength, 2s
Line To Ground:
2kV AC
Line To Ground (B-Type):
2,5kV AC
Line To Line:
760V AC
Temperature Range:
-25...+100°C
Part Nr.
IR
L
CX
CY
IL
[A]
[mH]
[nF]
[nF]
[µA]
FN406-0.5-02
0,5
24
100
2,2
373
FN406-1-02
1
12
100
2,2
373
FN406-3-02
3
2,5
100
2,2
373
FN406-6-02
6
0,78
100
2,2
373
FN406-8.4-02
8,4
0,3
100
2,2
373
FN406B-0.5-02
0,5
24
100
2
FN406B-1-02
1
12
100
2
FN406B-3-02
3
2,5
100
2
FN406B-6-02
6
0,78
100
2
FN406B-8.4-02
8,4
0,3
100
2
IR = Rated Current, at 40°C, L = Inductance, IL = Leakage Current, Max. at 230V, 50Hz