MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Independent control gear • Wide range input • Aluminum housing IP65/IP67 • Constant power supply (CP mode) • Overload protection by current limiting, auto recovery • Protected against short circuit, overtemperature, overvoltage • Built-in PFC circuit • For LED and lighting applications • Safety standards: EN61347-1 and others • EMC standards: EN55015, EN61000-3-2 class C and others • 5 years manufacturer warranty • HVGC-480-_: IP67, voltage and current fixed, not dimmable • HVGC-480-ADA: IP67, DALI interface, adjustable via internal potentiometer
Technical Specifications
Input Voltage:
180...528V AC (47...63Hz)
254...747V DC
Input Inrush Current, Max.:
40A
Withstand Voltage
I/P-O/P:
3750V AC
I/P-FG:
2000V AC
O/P-FG:
1500V AC
Operating Temperature:
-40...+90°C
Dimensions(LxWxH):
262x125x43.8mm
Weight:
2800g
I/P = Input, O/P = Output, FG = Frame Ground
Part Nr.
UA
Iadj
PA
URN
h
[V]
[mA]
[W]
[%]
[%]
HVGC-480-L
137...343
700...1750
480
5
94,5
HVGC-480-M
92...228,5
1050...2625
480
5
94,5
HVGC-480-H
68...171,5
1400...3500
480
5
94,5
HVGC-480-L-ADA
137...343
700...1750
480
5
94,5
HVGC-480-M-ADA
92...228,5
1050...2625
480
5
94,5
HVGC-480-H-ADA
68...171,5
1400...3500
480
5
94,5
UA = Output Voltage, Iadj = Output Current Adjustment, PA = Output Power, URN = Ripple & Noise, Max @ Rated Current, h = Typ. Efficiency