MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
You will find suitable isolation assemblies and heatsinks in our blue "Passive and Electromechanical Components" catalogue starting at product group G9111.
Thermolubricants are available in the red "Components and Devices" catalogue from product group R3211.
Technical Specifications
Part Nr.
UCES
IC25
ICpuls
Ptot
UGE(th)
td(on)
td(off)
[V]
[A]
[A]
[W]
[V]
[ns]
[ns]
STGF10NC60KD
600
9
30
25
4,5
17
72
STGF14NC60KD
600
11
50
28
4,5
22,5
116
STGF19NC60HD
600
16
60
32
3,75
25
97
STGF30H60DF
600
60
120
37
5,0
50
160
STGP6NC60HD
600
15
21
56
3,75
12
76
STGP7NC60HD
600
25
50
80
3,75
18,5
72
STGP8NC60KD
600
15
30
65
4,5
17
72
STGP10NB60SD
600
29
80
80
2,5
700
1200
STGP10NC60KD
600
20
30
65
4,5
17
72
STGP19NC60HD
600
40
60
130
3,75
25
97
STGP19NC60KD
600
35
75
125
4,5
30
105
STGP19NC60WD
600
40
35
125
3,75
25
90
STGP20V60DF
600
40
80
167
5,0
38
149
STGP30H60DF
600
60
120
260
5,0
50
160
STGP30V60DF
600
60
120
258
5,0
45
189
UCES = Max. Collector-Emitter Breakdown Voltage, IC25 = Max. Continuous Collector Current At TC = 25°C, ICpuls = Max. Pulsed Collector Current, Ptot = Power Dissipation, UGE(th) = Min. Gate Threshold Voltage, td(on) = Turn-On Delay Time, td(off) = Turn-Off Delay Time, TC = Case Temperature
Terms of Delivery
Minimum order quantity: please see price list column "MOQ".