MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
• You will find suitable High Power LED Module here
• You will find Inrush Current Limiters at product group M7564
• You will find Connectors from product group F9811
• You will find Potentiometers at product groups C3211 and C3212
Features
• Independent control gear • Universal input • Aluminum housing IP65 • Not dimmable • Overload protection by current limiting, auto recovery • Adjustable current limitation via internal potentiometer • Constant current • High output voltage • Protected against short circuit, overload, overvoltage • Built-in PFC circuit • For LED and lighting applications • EN61000-3-2, Class C, EN55015, EN61347-1, EN61347-2-13
Technical Specifications
Input Voltage:
90...305V AC (47...63Hz)
127...431V DC
Input Inrush Current, Max.:
60A
Withstand Voltage
I/P-O/P:
3750V AC
I/P-FG:
2000V AC
O/P-FG:
1500V AC
Operating Temperature:
-40...+70°C
Dimensions(LxWxH):
195.6x61.5x38.8mm
Weight:
840g
I/P = Input, O/P = Output, FG = Frame Ground
Part Nr.
UA
Iadj
PA
URN
h
[V]
[mA]
[W]
[%]
[%]
HLG-80H-C350A
128...257
210...350
89,95
5
91,5
HLG-80H-C350B
167...257
350
89,95
5
91,5
HLG-80H-C350AB
128...257
210...350
89,95
5
91,5
HLG-80H-C700A
64...129
420...700
90,3
5
91,5
HLG-80H-C700B
84...129
700
90,3
5
91,5
HLG-80H-C700AB
64...129
420...700
90,3
5
91,5
UA = Output Voltage, Iadj = Output Current Adjustment, PA = Output Power, URN = Ripple & Noise, h = Typ. Efficiency
Note
Power supply for the operation of LED light sources.
These products are not designed for operation in idle state.