MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Resettable switching device • Low current loss due to a low resistance in normal use • Protection against overcurrent and short circuit The mode of action is based on the PTC effect. In standard use, the resistance of the device is very low so that only a small power loss arises. In the event of an error, short-circuit or overcurrent, the resistance value of this device increases and protects the equipment. After eliminating the error and switching off the supply voltage, the device quickly returns to a low impedance state.
Application
• General electronics up to a maximum voltage of 16V, such as: audio equipment, automotives electronic, fire alarm and security systems, halogen light, medical and test equipment, wire harness etc.
Technical Specifications
Insulating Material:
Epoxy Polymer (UL94V-0)
Lead Wires:
Ø 0,81mm, Tin-plated copper
Operating Voltage, Max.
16V
Interrupting Current, Max.:
100A
Temperature Range:
-40...+85°C
Resistance to Soldering Heat:
260°C/5s
Part Nr.
IN
R1Max
tTrip
Pd
AMax
BMax
CMax
ERFRG_
[A]
[Ohm]
[s]
[W]
[mm]
[mm]
[mm]
3001600Z
3,0
0,105
2,0
2,3
7,1
11,0
5,1
4001600Z
4,0
0,063
3,5
2,4
8,9
12,8
5,1
5001600Z
5,0
0,044
3,6
2,6
10,4
14,3
5,1
6001600Z
6,0
0,033
5,8
2,8
10,7
17,1
5,1
7001600Z
7,0
0,021
8,0
3,0
11,2
19,7
5,1
8001600Z
8,0
0,018
9,0
3,0
12,7
20,9
5,1
9001600Z
9,0
0,015
12,0
3,3
14,0
21,7
5,1
IN = Rated Current, R1Max = 1 Hour Post-Trip Resistance Standard Trip, tTrip = Max. Time to Trip at 5xIN, Pd = Typical Power; All Data for Ambient Temperature at 23°C
Note
• These components are protected against overcurrent and overtemperature; not for continuous repeatable switching operations. • The valid VDE regulations must be observed when handling products which come into contact with electrical voltage.