MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
You will find suitable power supply cables in product groups G2121, G2123 und G2128.
You will find suitable power supply cables (export) in product group G2351.
You will find installation material in product group L9985.
You will find suitable filters in product group D3213 You will find suitable connectors here. hier.
Features
• 300% peak load capability for maximum 5 seconds • Enclosed case, screw terminals • Universal input • Built-in active PFC function • High efficiency up to 89% • Protections: short circuit, overload, over voltage, over temperature • Safety standards:: UL 62368-1, EN 62368-1 • EMC standards: EN 55032 Class B • 5 years warranty
Technical Specifications
Input Voltage:
85...264V AC
120...370V DC (47...63 Hz)
Input Inrush Current, Max.:
75A
Operating Temperature:
-40...+70°C
Withstand Voltage
I/P-O/P:
3000V AC
I/P-FG:
2000V AC
O/P-FG:
500V AC
Dimensions:
199x105x41mm
Weight:
900g
I/P = Input, O/P = Output, FG = Frame Ground
Part No.
UA
IA
PA
ΔUA
URN
ƞ
[V]
[A]
[W]
[%]
[mVp-p]
[%]
HRP-150N3-12
12
0...13
156
±1,5
120
88
HRP-150N3-24
24
0...6,5
156
±1,5
150
88
HRP-150N3-36
36
0...4,3
154,8
±1,5
200
89
HRP-150N3-48
48
0...3,3
158,4
±1,5
240
89
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency
Note
These power supplies are considered as a component that has to be installed in a final equipment.