MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Note
You will find suitable crimp housings in product group F1444.
You will find suitable fans in product group K1121.
You will find suitable power supply cables (export) in product group G2351.
You will find suitable power supply cables in product groups G2313, G2315 and G2319.
You will find suitable connectors here.
Features
• Open frame • Compact case, 5'' x 3'' • Contact pin for nylon-crimp terminals • Universal input • 250W with free air convection, 400W with 25cfm forced air • Overload protection, pulsing hiccup shutdown, auto recovery • Protections: short circuit/over load/over voltage • Built-in active PFC function • Low no load power consumption • Built-in auxiliary power 12V/0,5A • Safety standards: UL60950-1, EN60950-1 • EMC standards: EN55032 Class B • 3 years manufacturer warranty
Technical Specifications
Input Voltage:
80...264V AC (47...63Hz)
113...370V DC
Input Inrush Current, Max.:
80A
Leakage Current, Max.:
0,75mA
Over Load Protection:
105...135%
Withstand Voltage
I/P-O/P:
3000V AC
I/P-FG:
2000V AC
O/P-FG:
500V AC
Operating Temperature:
-30...+70°C
Weight:
390g
I/P = Input, O/P = Output, FG = Frame Ground
Part Nr.
UA
IA
PA
DUA
URN
h
[V]
[A]
[W]
[%]
[mVp-p]
[%]
EPP-400-12
12
33,3
399,6
3
120
91,5
EPP-400-15
15
26,7
400,5
3
150
92
EPP-400-24
24
16,7
400,8
2
200
93
EPP-400-27
27
14,9
402,3
1
200
93,5
EPP-400-36
36
11,2
403,2
1
250
93
EPP-400-48
48
8,4
403,2
1
250
94
UA = Output Voltage, IA = Output Current Range, Max., With 25cfm Forced Air, PA = Output Power, Max., With 25cfm Forced Air, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency
Note
These power supplies are considered as a component that has to be installed in a final equipment.
Norms
Certified to EN60335-1 as of production date 03.12.2019