MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• For DIN rail mounting • Can be installed on DIN rali TS-35/7.5 or 15 • Width only 63mm • DC output adjustable • Cooling by free air convection • Protection: short circuit, overload, over voltage, over temperature, input reverse polarity and Undervoltage cut-off/input • Safety standards: UL 62368-1, IEC 62368-1 • EMC standards: EN 55032 Class B • 3 years manufacturer warranty
Technical Specifications
Input Voltage:
See Table
Overload Protection:
105...135%
Withstand Voltage
I/P-O/P:
4000V AC
I/P-FG:
2000V AC
O/P-FG:
2000V AC
Operating Temperature:
-40...+80°C
Weight:
845g
I/P = Input, O/P = Output, FG = Frame Ground
Part No.
UE
UA
IA
Uadj
DUA
URN
h
[V DC]
[V]
[A]
[V]
[%]
[mVp-p]
[%]
DDRH-120-12
250...1500
12
0...8,4
12...15
1,5
120
84
DDRH-120-24
250...1500
24
0...5
24...29
1
240
86
DDRH-120-32
250...1500
32
0...3,75
30...36
1
240
87
DDRH-120-48
250...1500
48
0...2,5
48...58
1
300
87
UE = Input Voltage Range, UA = Output Voltage, IA = Output Current Range, Uadj = Output Voltage Adjustment, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency