MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Modified sine wave output • Power On/Off switch • Front panel indicator for operation status • Battery low alarm, Battery low shutdown • Protections: over voltage/over temperature/overload/output short/input reverse polarity • Built-in fan On/Off control function
Technical Specifications
Input Voltage:
See Table
Output Voltage:
230V AC
Output Frequency:
50Hz ±1%
Output Rated Power:
2500W
Output Surge Power:
5000W
Wave Form:
Modified Sine Wave
Overvoltage
A301-2K5-F3:
15...17V
A302-2K5-F3:
30...32V
Operating Temperature
100% Load:
0...+25°C
Weight:
8700g
Part Nr.
UE
IE
UBA
UBL
h
[V]
[A]
[V]
[V]
[%]
A301-2K5-F3
10...15
250
10±0,5
9,5±0,5
82
A302-2K5-F3
21...30
130
21±0,8
20±0,8
85
UE = Input Voltage Range, IA = Input Current, UBA = Battery Low Alarm, UBL = Battery Shutdown, h = Efficiency
Note
Before using the DC/AC converter, please ensure that your terminal equipment has been approved by the manufacturer for operation with modified sine-wave voltage (trapezoid).