MOQ (minimum order quantity) PU (Price unit): E (item), H (100 items), T (1000 items), p (pair), P (pack), k (kilogram), h (100 meters) RRP recommended retail price. Stock and prices are updated on an hourly basis. After Registration and Login you will see your individual customer prices and CSV file upload, watchlists and requestlist are accessible in the Customer Portal. All prices are net excluding V.A.T. We do not deliver to private end-users.
Features
• Metal enclosure and standard connectors • Compact case 2”x4” • Universal input • Overload protection by switching off (hiccup mode) • Integrated EMV filter • For medical technology applications (2x MOPP) • Protected against short circuit, overload and overvoltage • EMC standards: EN60601-1-2, Class B, EN61000-4-2, EN55032, Class B • 3 years manufacturer warranty
Technical Specifications
Input Voltage:
80…264 VAC (47..63 Hz)
120…370 V DC
Inrush Current:
60 A
No load Power Consumption, typ.:
0,1 W
Overload Protection:
105…120 %
Withstand Voltage I/P-O/P:
4800 V AC
Operating Temperature:
-40...+85°C
Dimension (LxWxH):
118,3 x 62,7 x 38,7 mm
Weight:
167g
Part No.
UA
IA
PA
ΔUA
ƞ
[V]
[A]
[W]
[%]
[%]
RACM60-12SK/ENC/2x4
12
5
60
± 2
90
RACM60-24SK/ENC/2x4
24
2,5
60
± 2
90
UA = Output Voltage, IA = Output Current, PA = Output Power, DUA = Output Voltage Tolerance, h = Efficiency
Note
These power supply units are intended for installation in terminal equipment.